Summary: why water treatment matters in Oman and the Gulf
In Oman and most Gulf states, city drinking water comes mainly from desalination plants, and each cubic metre depends on several chemicals. The French Institute of International Relations (Ifri, September 2022) reports the share of drinking water that comes from desalination as 86% for Oman, 90% for Kuwait, 70% for Saudi Arabia and 42% for the UAE. These figures refer to 2022.
Across the Middle East, a review in npj Clean Water reports contracted desalination capacity of about 60.1 million m³/day by the end of 2023 (46.9% of the world total). Capacity actually operating at that time was about 28.96 million m³/day (41.8% of the world total). Contracted capacity includes projects under construction and planned ones, which is why it exceeds active capacity.
In Oman, Nama PWP (the single buyer of power and water) forecasts that peak water demand on the Main Interconnected System (MIS) will grow about 3% a year, from 1.211 million m³/day in 2025 to about 1.483 million in 2032. Almost all operating desalination plants in Oman use reverse osmosis (RO). The one large thermal unit, Barka I (MSF), is held in reserve.
Water-quality basics and key parameters
Every treatment process is designed to correct a few specific parameters, and chemicals are used to move exactly those parameters. Each term is defined once here.
| Parameter | Plain meaning | Usual unit | Why it matters |
|---|---|---|---|
| Turbidity | Cloudiness caused by fine suspended particles | NTU | Particles shield microbes from disinfectant and clog membranes |
| Total dissolved solids (TDS) | Total of salts and other dissolved matter | mg/L | Gulf seawater is very salty; the main job of a desalination plant is to cut TDS |
| pH | How acidic or alkaline the water is (0–14, 7 is neutral) | — | Directly affects pipe corrosion, chlorine action and coagulant performance |
| Alkalinity | Capacity to neutralise acid, mainly from bicarbonate and carbonate | mg/L as CaCO₃ | RO permeate has very little alkalinity and is corrosive, so it must be restored |
| Hardness | Amount of calcium and magnesium ions | mg/L as CaCO₃ | Cause of scale in boilers, cooling towers and membranes |
| SDI (silt density index) | Test of how strongly water tends to clog a filter or membrane | no unit | RO membrane makers usually ask for SDI below 5, preferably below 3, in feed water; the exact limit is in each maker's data sheet |
| Residual chlorine | Chlorine left in water after disinfection | mg/L | Prevents recontamination in the network, but damages RO membranes |
| BOD and COD | Oxygen needed to break down organic matter (biological and chemical) | mg/L | Main pollution indicators for wastewater |
| LSI (Langelier index) | Shows whether water tends to deposit calcium carbonate or to corrode | no unit | Used to set water stability in post-treatment |
Other terms used below:
- Dosing
- The amount of chemical added per litre of water, usually in mg/L or ppm.
- Coagulation
- Neutralising the electric charge of suspended particles so they can stick together.
- Flocculation
- Gentle stirring so neutralised particles form larger clumps (floc).
- Biofouling
- Growth of microbes and a slimy layer on a membrane or pipe surface.
- Scaling
- Deposit of poorly soluble salts, such as calcium carbonate and calcium sulphate, on surfaces.
- Brine
- Very salty water that leaves a desalination plant and is returned to the sea.
Oman's drinking-water limits are set in Omani Standard OS 8/2012 (non-bottled drinking water). It replaced OS 8/2006 and is based on the WHO Guidelines for Drinking-water Quality (2011 edition). The full text can be bought from Oman's Directorate General for Specifications and Measurements (DGSM).
Drinking-water treatment stages and the chemicals at each
Conventional treatment of surface or ground water has seven stages in sequence. In Oman many of the same stages run as pretreatment ahead of the RO membrane. This section follows standard water-engineering knowledge, and a specific reference has not yet been added.
- Intake and screening. Water is drawn from the sea, a dam or a well, and coarse debris is removed by screens.
- Chemicals Sodium hypochlorite or chlorine, dosed in shocks or continuously at a sea intake so that shells, algae and marine life do not grow in the pipes.
- Coagulation. A coagulant is added with fast mixing.
- Chemicals Polyaluminium chloride (PAC), aluminium sulphate (alum), ferric chloride (FeCl₃) and ferric sulphate. Iron salts, mainly ferric chloride, are most common in seawater desalination.
- Aluminium and iron coagulants consume alkalinity, so lime, caustic soda or sodium bicarbonate is sometimes dosed alongside. PAC consumes less alkalinity than alum and makes less sludge.
- Flocculation. Slow mixing builds large floc.
- Chemicals Polyelectrolytes: water-soluble charged polymers, above all polyacrylamide (PAM) in cationic, anionic and non-ionic forms, and polyDADMAC.
- Sedimentation or flotation (DAF). Floc settles in a basin, or rises to the surface on fine air bubbles in dissolved air flotation (DAF). DAF has become important in Gulf desalination for dealing with algal blooms (red tide).
- Filtration. Water passes through sand or multi-layer filters (sand, anthracite), activated carbon filters and, increasingly, ultrafiltration (UF) membranes.
- Chemicals Activated carbon (powder and granular) removes odour, taste and organics. UF membranes are cleaned with hypochlorite, caustic soda and acids (citric or sulphuric).
- Disinfection. Kills bacteria and viruses and leaves a residual in the network.
- Chemicals Chlorine gas; sodium hypochlorite (liquid, sometimes made on site by electrolysing brine); calcium hypochlorite (solid, for small scale); chlorine dioxide; ozone. UV light is not a chemical. Ammonia is sometimes added to form chloramine, a more persistent disinfectant.
- pH adjustment and stabilisation. Final water should be neither corrosive nor scale-forming.
- Chemicals To raise pH and alkalinity: caustic soda, hydrated lime, soda ash (sodium carbonate) and sodium bicarbonate. Bicarbonate raises alkalinity more than pH, which makes it a safe, easily controlled way to add buffering capacity. To lower pH: sulphuric acid, hydrochloric acid or CO₂ gas.
- Optional: corrosion inhibitors such as orthophosphate and polyphosphate to protect pipes, and fluoride in some countries.
Desalination plants: RO and thermal, and their chemicals
Oman's desalination plants are mainly reverse osmosis, so the main chemical market in Oman is pretreatment and membrane-care chemicals for RO.
Two technology families
- Reverse osmosis (RO). Salty water is pushed at high pressure through a very fine membrane, and the salt stays behind. It uses less energy, but the membrane is sensitive to turbidity, microbes, scale and chlorine.
- Thermal (MSF and MED). In multi-stage flash (MSF) and multi-effect distillation (MED), seawater is evaporated and condensed again. These plants are usually built beside a power station and hold a large legacy share in the region, but most new projects in the region are RO. The exact share of each technology by country will be given with official data in later studies.
Oman's large desalination plants
Source for all rows: Nama PWP, Water 7-Year Statement 2026–2032, Issue 20. Capacity in m³/day.
| Plant | Region | Capacity (m³/day) | Technology | Status |
|---|---|---|---|---|
| Ghubrah III | Muscat (MIS) | 300,000 | RO | Under construction commercial operation February 2027 |
| Barka IV | Batinah (MIS) | 281,000 | RO | Operating |
| Sohar IV | North Batinah (MIS) | 250,000 | RO | Operating |
| Qurayyat | Muscat (MIS) | 200,000 | RO | Operating |
| Ghubrah II | Muscat (MIS) | 191,000 | RO | Operating |
| Sur II | Sharqiyah | 132,000 | RO | Operating (the document's table shows 131,000) |
| Barka II | Batinah (MIS) | 120,000 | RO | Operating |
| Salalah III | Dhofar | 113,650 | RO | Operating since 2021 |
| Barka V | Batinah (MIS) | 100,000 | RO | Operating |
| Barka I | Batinah (MIS) | 91,200 | MSF | Emergency reserve |
| Aseelah | Sharqiyah | 80,000 | RO | Operating |
| Salalah IWPP | Dhofar | 68,190 | RO | Operating since 2012 |
Future projects in the same document: North Batinah IWP at 150,000 m³/day (target 2032) and Dhofar Water IWP at 80,000 m³/day (2030). The document does not state a national total. Adding the operating RO rows in the table gives about 1.54 million m³/day. That sum is the author's own calculation, not an official figure, and it leaves out small and private units.
Chemicals in an RO plant, in the order of the water path
- Sea intake: sodium hypochlorite (or electrolytic chlorination of seawater) to prevent biological growth.
- Pretreatment: ferric chloride or ferric sulphate as coagulant, a polymer as coagulant aid, sulphuric acid to set the coagulation pH, then DAF, sand filters or UF.
- Before the membrane:
- Sodium bisulfite (SBS) or sodium metabisulfite (SMBS) removes residual chlorine, because chlorine destroys a polyamide membrane.
- Antiscalant: a product that, at a very low dose, stops salts from depositing on the membrane. Common types are phosphonates (such as ATMP and HEDP), polyacrylates and phosphorus-free "green" antiscalants. These are usually blended, branded products.
- Sulphuric acid (in some designs) lowers pH to prevent calcium carbonate scale.
- A non-oxidising biocide such as DBNPA, used periodically against biofouling.
- Clean-in-place (CIP): acid solutions (citric or hydrochloric acid) to dissolve mineral scale and iron, and alkaline solutions (caustic soda with cleaners such as EDTA and SDS) to remove biological and organic layers.
- Post-treatment and remineralisation: RO permeate is almost free of minerals and is corrosive, so calcium and alkalinity must be put back. Usual methods:
- Hydrated lime plus CO₂ (most common at large scale).
- A calcite bed (crushed limestone) with CO₂ or sulphuric acid.
- Sodium bicarbonate (baking soda) with calcium chloride, or bicarbonate alone to raise alkalinity. It is simpler but usually costlier, so it is used mostly in small and medium plants or for final correction.
Which method each Omani plant actually uses decides the size of the sodium bicarbonate market. This is the key question of the first study. - Final: chlorination with hypochlorite or chlorine, and pH adjustment with caustic soda.
Chemicals in a thermal plant (MSF / MED)
- High-temperature antiscalant (polymaleic acid types and phosphonates) to prevent scale on heat-transfer tubes.
- Antifoam to control foam in the evaporation chambers.
- Oxygen scavenger, such as sodium bisulfite, to reduce corrosion.
- Acid for periodic descaling, and the same RO-style remineralisation at the outlet.
Municipal and industrial wastewater treatment
In the Gulf, wastewater is not simply discarded. Because water is scarce, treated sewage effluent (TSE) is reused for landscape irrigation and industrial uses. In Oman this sits with Nama Water Services (formerly Haya Water). The volume of treated wastewater and the reuse share will be taken from official reports in later studies.
Main stages and chemicals:
- Primary treatment: screening, grit removal and primary settling. Hydrogen sulphide odour is controlled with calcium nitrate, iron salts, hypochlorite or hydrogen peroxide.
- Biological treatment (activated sludge or MBR): microbes consume organic matter. MBR is a bioreactor combined with a micro- or ultrafiltration membrane. Chemicals: caustic soda or sodium bicarbonate to supply the alkalinity needed for nitrification (conversion of ammonia to nitrate, which consumes alkalinity); methanol or another carbon source for nitrogen removal; and MBR membrane cleaners (hypochlorite, citric acid).
- Phosphorus removal: chemical precipitation with ferric chloride, alum or PAC.
- Advanced treatment and disinfection: filtration, chlorination or UV.
- Sludge handling: surplus sludge is thickened and dewatered with cationic polymer (PAM), one of the largest uses of water-soluble polymers. Lime is sometimes added to stabilise sludge.
Industrial wastewater (refineries, petrochemicals, oil and gas produced water) has its own chemicals: demulsifiers to separate oil from water, coagulants and polymers for DAF and IAF units, and acid and caustic for neutralisation. With the industrial complexes at Sohar and Duqm and Oman's oil and gas sector, this segment matters for market studies.
Industrial water: cooling towers and boilers
Refineries, petrochemical plants, power stations and district cooling systems are steady buyers of water chemicals in the Gulf. The region's heat raises the load on cooling towers.
Cooling tower
Water evaporates in the tower and salts concentrate. The three main problems are scale, corrosion and biological growth, including Legionella bacteria.
- Antiscalants and dispersants: phosphonates, polyacrylates.
- Corrosion inhibitors: phosphates, zinc salts, azole derivatives (such as TTA) to protect copper.
- Oxidising biocides: hypochlorite, chlorine, bromine compounds (such as BCDMH), chlorine dioxide.
- Non-oxidising biocides: isothiazolinones, DBNPA, glutaraldehyde.
- Sulphuric acid for pH and alkalinity control.
Boiler
Boiler water must be nearly free of hardness and oxygen. It is usually prepared first with ion-exchange resin or RO, and then with chemicals.
- Softening and ion exchange: salt (sodium chloride) to regenerate softener resin, and hydrochloric acid and caustic soda to regenerate demineralising resin.
- Oxygen scavengers: sodium sulphite, hydrazine, DEHA, carbohydrazide.
- Phosphate and polymer programmes to control scale inside the boiler.
- Neutralising and film-forming amines (such as morpholine and cyclohexylamine) to protect the condensate return line.
- Caustic soda for boiler-water pH.
Master table of water treatment chemicals
The table collects every chemical named above. The HS code (six-digit Harmonized System customs code) is given for finding import statistics in later studies. Codes were matched to general classification tables at six digits; formulated products have no specific code, and a country's own tariff may differ at the seventh and eighth digits.
| Chemical | English name / formula | Main role | Where used | HS code (approx.) |
|---|---|---|---|---|
| Sodium bicarbonate (baking soda) | NaHCO₃ | Raises alkalinity and stability | RO post-treatment, pools, biological wastewater | 283630 |
| Polyaluminium chloride | PAC, Alₙ(OH)ₘCl₃ₙ₋ₘ | Coagulant | Coagulation, phosphorus removal | 282732 |
| Aluminium sulphate (alum) | Al₂(SO₄)₃ | Coagulant | Coagulation | 283322 |
| Ferric chloride | FeCl₃ | Coagulant (common in seawater RO pretreatment) | Coagulation, phosphorus, odour | 282733 |
| Polyacrylamide and polyelectrolytes | PAM, polyDADMAC | Flocculant, sludge dewatering | Flocculation, sludge | 390690 |
| Sodium hypochlorite | NaOCl | Disinfectant, anti-biofouling | Intake, disinfection, membrane cleaning | 282890 |
| Chlorine (liquid/gas) | Cl₂ | Disinfectant | Disinfection | 280110 |
| Calcium hypochlorite | Ca(OCl)₂ | Disinfectant (solid) | Small-scale disinfection, pools | 282810 |
| Caustic soda | NaOH | pH rise, alkaline cleaning, resin regeneration | Post-treatment, CIP, boilers | 281511 / 281512 |
| Soda ash | Na₂CO₃ | pH and alkalinity rise, lime-soda softening | pH adjustment, softening | 283620 |
| Hydrated lime | Ca(OH)₂ | Remineralisation, pH rise, sludge stabilisation | RO post-treatment, sludge | 252220 |
| Carbon dioxide | CO₂ | With lime, forms calcium bicarbonate | RO post-treatment | 281121 |
| Calcium chloride | CaCl₂ | Adds calcium | RO post-treatment (with bicarbonate) | 282720 |
| Antiscalants | Phosphonates, polyacrylates | Scale prevention | Before RO membrane, thermal, cooling tower | 382499 or 293190 (by formula) |
| Sodium bisulfite / metabisulfite | SBS / SMBS, NaHSO₃ / Na₂S₂O₅ | Chlorine removal, oxygen scavenger | Before membrane, thermal, boilers | 283210 |
| Sulphuric acid | H₂SO₄ | pH reduction | RO pretreatment, cooling tower, calcite remineralisation | 280700 |
| Hydrochloric acid | HCl | Acid cleaning, resin regeneration | CIP, boilers | 280610 |
| Citric acid | C₆H₈O₇ | Membrane cleaning | CIP of RO and UF membranes | 291814 |
| Non-oxidising biocides | DBNPA, isothiazolinones | Biological control | RO membrane, cooling tower | 380894 |
| Activated carbon | — | Adsorbs organics, odour, taste | Filtration | 380210 |
| Sodium chloride (industrial salt) | NaCl | Resin regeneration, on-site hypochlorite | Softeners, electrochlorination | 250100 |
| Corrosion inhibitors and oxygen scavengers | Phosphates, azoles, DEHA, hydrazine | Metal protection | Cooling tower, boilers, network | varies |
Next studies: chemicals in order of priority
Each chemical gets its own study covering use in Oman and the Gulf, imports and customs unit values, and the large producers. Method: the destination country's customs data first, then global databases, in calendar years, with one table per country.
- Sodium bicarbonate (baking soda) in water treatment: first priority. Key question: which desalination plants in Oman and the region use baking soda for remineralisation, and where Oman's HS 283630 imports come from.
- Polyaluminium chloride (PAC) and related coagulants (alum, ferric chloride).
- Sodium hypochlorite and chlorine, including calcium hypochlorite and on-site generation.
- Caustic soda: use in water and other industries, and its link to chlorine (both come from the chlor-alkali process).
- Antiscalants and membrane chemicals (antiscalant, SBS, biocides, CIP chemicals): a high-value, brand-driven market.
Candidates for after these five: ferric chloride, polyacrylamide, hydrated lime, sulphuric acid and soda ash.
Sources and limits
Sources
- Nama PWP, Water 7-Year Statement 2026–2032, Issue 20. Primary official source for plant capacities and demand forecast (omanpwp.om).
- npj Clean Water, volume 9. Review of Middle East desalination; contracted and operating capacity. Reported by Oman Observer, 9 March 2026, "Oman among key producers as Mideast leads global desalination".
- Ifri, The Geopolitics of Seawater Desalination, Études de l'Ifri, September 2022. Share of drinking water from desalination in Gulf states (ifri.org).
- Oman Observer, 24 February 2020: "GCC states account for 40pc of global water desalination capacity".
- Arab Center Washington DC, 12 April 2023: "The Costs and Benefits of Water Desalination in the Gulf".
- Times of Oman, 6 May 2023: "Oman ranked second in desalinated water use among Gulf countries".
- Omani Standard OS 8/2012, Un-bottled Drinking Water, DGSM (replaces OS 8/2006).
- WHO, Guidelines for Drinking-water Quality, 4th edition (2011).
The technical sections (treatment stages and the role of each chemical) follow standard water-engineering knowledge. For further reference see the WHO guidelines. Later studies give a named source for each chemical.
Limits of this article
- The desalination shares of drinking water (86% and the other countries) are for 2022.
- Middle East capacities in the npj Clean Water review are contracted capacities; operating capacity is 28.96 million m³/day.
- The remineralisation method at each Omani plant (lime and CO₂, calcite or baking soda) is examined in the baking soda study.
- HS codes must be checked against Oman's customs tariff; sodium bisulfite and metabisulfite are classified separately in some tariffs.
- Treated wastewater volume and reuse in Oman have not yet been taken from Nama's annual report.
- The total of 1.54 million m³/day is the author's own calculation and not an official figure.
Need a market study for your product in Oman?
Tell me which chemical market you are exploring. Summary studies are free; a full study with customs data, prices and producer profiles is available on request.
Contact: info@westasiachem.com